Lined Ball Valve

Manufacturer and Exporter of PTFE / FEP / PFA / PVDF Lined Ball Valve For Corrosive Application

Compact Design, Easy Operation and Lining Integrity For A Longer Life

Ball Valves are a workhorse and omnipresent in chemical plants. Ball valves are used for an on-off purpose. It is used in process lines, product lines, utility lines, etc.

ICON offers PTFE / FEP / PFA / PVDF lined ball valves. These lined valves are used for highly corrosive chemicals where higher alloy materials are costlier than lined ones, thus protecting the expensive equipment, extending the life of it and assuring superior performance.

The material selection for fluorocarbons lining of valves will depend on working conditions like chemical and mechanical characteristics of the fluid flowing inside the pipe, valves, temperature, etc.

Unique Features of Lined Ball Valve

  • Lining offered PTFE / FEP / PFA / PVDF. The thickness of the lining is between 3.5 to 6 mm.
  • The lining resins from renowned manufacturers like DuPont, Daikin, GFC.
  • Virgin PTFE, FEP, PFA to withstand temperature from -20 C to +240C.
  • Compact design Ball Valves occupy less space.
  • Quarter turn operation makes it simple and easy to operate.
  • Study Flow without any hurdle.
  • Control option- Manual as well as Automatic Control.
  • Type of Automatic Control- Rotary Actuators, mounted for Automatic Actuation of Ball Valves.
  • Other accessories such as solenoid valve, L.S.MOR as per requirement
  • Anti- Static lining available on request.
  • Tested as per API 598
  • Valve outer body offered in In Stainless Steel 316 and mirror polished.
  • Material OF Construction- Cast Iron, Carbon Steel, Stainless Steel and As per requirement. ICON also supplies PTFE Lined Valves, Lined Pipe Fittings and accessories like PTFE Lined Instrument Tee, Lined Sparger, Flow Indicator and Lined Y Strainer to be used in conjunction with lined Pipe and Valves.It is used by the leading Chemical, Pharmaceutical, Bulk Drug manufacturers.
  • Call Mr.Sanjay on +919819134484 for a quick reply!

Cross Section Manual Lined Ball Valve

CROSS-SECTION-MANUAL-LINED-BALL-VALVE

Description of Manual Lined Ball Valve

SR. NO. DECRIPTION METERIAL QTY
1 SPLIT BODY CS/CF8/CF8MX FEP/PFA LINED 2
2 BALL WITH STEM CF8/CF8M X FEP/PFA LINED 1
3 LINING FEP/PFA LINING 3 TO 5 MM 1
4 SEAT RINGS VIRGIN PTFE 2
5 GLAND RINGS VIRGIN PTFE 3
6 GLAND PUSHER CF-8 1
7 MANUAL HAND LEVER M.S. / SS 1

Dimensions of Manual Lined Ball Valve

SIZE CLASS – 150# TORQUE WEIGHT
NB A B C D M N P.C.D. NM KG
3/4″ 127 11.2 43 98 16 4 69.8 10 3.00
1″ 127 11.2 51 108 16 4 79.2 10 4.00
1 1/2″ 165 14.3 73 127 16 4 98.5 15 8.00
2″ 178 16 92 152 19 4 120.6 21 10.00
3″ 203 19 127 190.5 19 4 152.4 45 16.00
4″ 229 24 157 229 19 8 190.5 210 24.00
6″ 267 25 216 279 22 8 241.3 310 45.00

Technical Data of Manual Lined Ball Valve

TECHNICAL DATA
DESIGN & MANUFACTURING STD.
BS 5351 / ISO 17292
TESTING & INSPECTION STD.
API 598 / ISO 12266
FACE TO FACE :
AS PER ANSI B 16.10
END CONNECTIONS :
FLANGED AS PER ANSI B 16.5 150#.
STANDARD RESIN SPECIFICATION:
FEP : ASTM D 2116 / PFA : ASTM D 3307

PRIMARY SERVICE RATING & TEST PRESSURE
CLASS WORKING HYD. TEST PRESSURE
PRESSURE BODY SEAT TEMP.
150 100 PSIG 225 PSIG 150 PSIG 150/200°C
AIR TEST-SEAT 80 PSIG ±10 PSIG; SPARK TEST: 10 KVA

GET IN TOUCH WITH US

    Cross Section Actuated Lined Ball Valve

    CROSS-SECTION-ACTAUTED-LINED-BALL-VALVE

    Description of Actuated Lined Ball Valve

    SR. NO. DECRIPTION METERIAL QTY
    1 SPLIT BODY CS/CF8/CF8MX FEP/PFA LINED 2
    2 BALL WITH STEM CF8/CF8M X FEP/PFA LINED 1
    3 LINING FEP/PFA LINING 3 TO 5 MM 1
    4 SEAT RINGS VIRGIN PTFE 2
    5 GLAND RINGS VIRGIN PTFE 3
    6 GLAND PUSHER CS / CF-8 1
    7 MANUAL HAND LEVER C.I. BODY 1
    8 SOLENOID VALVE ALUMINIUM BODY 3/2 OR 5/2 1
    9 ROTARY ACTUATOR ALUMINIUM BODY S/A OR D/A 1
    10 LIMIT SWITCH ALUMINIUM BODY 1

    Dimensions of Actuated Lined Ball Valve

    SIZE CLASS – 150# TORQUE WEIGHT
    NB A B C D M N P.C.D. NM KG
    3/4″ 127 11.2 43 98 16 4 69.8 10 3.00
    1″ 127 11.2 51 108 16 4 79.2 10 4.00
    1 1/2″ 165 14.3 73 127 16 4 98.5 15 8.00
    2″ 178 16 92 152 19 4 120.6 21 10.00
    3″ 203 19 127 190.5 19 4 152.4 45 16.00
    4″ 229 24 157 229 19 8 190.5 210 24.00
    6″ 267 25 216 279 22 8 241.3 310 45.00

    Technical Data of Actuated Lined Ball Valve

    TECHNICAL DATA
    DESIGN & MANUFACTURING STD.
    BS 5351 / ISO 17292
    TESTING & INSPECTION STD.
    API 598 / ISO 12266
    FACE TO FACE :
    AS PER ANSI B 16.10
    END CONNECTIONS :
    FLANGED AS PER ANSI B 16.5 150#.
    STANDARD RESIN SPECIFICATION:
    FEP : ASTM D 2116 / PFA : ASTM D 3307

    PRIMARY SERVICE RATING & TEST PRESSURE
    CLASS WORKING HYD. TEST PRESSURE
    PRESSURE BODY SEAT TEMP.
    150 100 PSIG 225 PSIG 150 PSIG 150/200°C
    AIR TEST-SEAT 80 PSIG ±10 PSIG; SPARK TEST: 10 KVA

    GET IN TOUCH WITH US